A vendor-neutral specification for an IP video intercom system covering villa and building door stations, indoor monitors, guard stations, SIP compatibility, door release hardware, mobile call forwarding, lift integration, testing and commissioning. Written for consultants, engineers and contractors to insert in tender documents for residential and commercial projects.

Vendor-neutral, no brand names. Review it against the code adopted for your project and fill in the values in [brackets].

PART 1 — GENERAL

1.1 Scope of Work

This section covers the supply, installation, configuration, testing, commissioning and handover of a complete IP video intercom system for [project name and location], comprising [number of buildings] buildings and [number of apartments / villas] residential units. The Contractor shall provide all equipment, software, licences, accessories, labour and documentation required for a fully operational system.

  • Outdoor door stations for [villa gates / building main entrances / compound gates], quantity as shown on the drawings.
  • Indoor video monitors in each residential unit, quantity [one per unit / as shown].
  • Guard (concierge) stations and/or management software at [security room / reception].
  • Door release interface: relay modules, electric locks, exit buttons, door contacts and lock power supplies, where included in this scope.
  • Mobile application service for call forwarding to residents' smartphones.
  • Lift control integration [required / not required].
  • PoE switches dedicated to the intercom system where not provided under the data network section.
  • Configuration, testing, training and as-built documentation.

1.2 Related Sections and Systems

  • Structured cabling system section: horizontal cabling, backbone, racks and labelling.
  • Data network (LAN) section: core and distribution switches, routing and internet connection.
  • Access control system: door hardware, card readers and shared door controllers, where applicable.
  • IP telephony system (IP-PBX), where intercom calls are routed to telephones.
  • Fire alarm system: release of electrically locked doors on alarm.
  • Lift installation: interface for floor access control.
  • IP CCTV system: viewing of selected cameras on indoor monitors.

1.3 Reference Standards

The system shall be designed, supplied and installed in accordance with the latest editions of the following standards, in addition to applicable Egyptian codes and regulations, including the Egyptian fire protection code for doors on escape routes:

  • IEC 62820 series — Building intercom systems, in particular IEC 62820-1-1 (System requirements — General).
  • RFC 3261 — SIP: Session Initiation Protocol.
  • RFC 3550 — RTP: A Transport Protocol for Real-Time Applications.
  • RFC 3711 — The Secure Real-time Transport Protocol (SRTP).
  • RFC 4733 — RTP Payload for DTMF Digits, Telephony Tones, and Telephony Signals.
  • ITU-T G.711 and G.722 (audio coding); ITU-T H.264 (video coding).
  • IEEE 802.3af and IEEE 802.3at — Power over Ethernet.
  • IEEE 802.1Q — Virtual LANs.
  • ANSI/TIA-568.2-D and ISO/IEC 11801-1 — Telecommunications cabling.
  • ANSI/TIA-606 — Administration (labelling) of telecommunications infrastructure.
  • IEC 60332-1, IEC 61034 and IEC 60754 — Fire performance of cables.
  • IEC 60529 — Degrees of protection provided by enclosures (IP code).
  • IEC 62262 — Degrees of protection against external mechanical impacts (IK code).
  • IEC 62368-1 — Audio/video, information and communication technology equipment: safety requirements.

1.4 Definitions

  • Door station: Outdoor unit with camera, microphone, loudspeaker and call buttons or keypad, installed at an entrance.
  • Indoor monitor: Unit inside the residential unit used to answer calls, view the visitor and release the door.
  • Guard station: Desktop unit or software used by security or reception staff to receive, place and transfer calls.
  • SIP: Session Initiation Protocol used to set up voice and video calls over IP.
  • Fail-safe lock: Lock that releases when power is removed; fail-secure lock: lock that stays locked when power is removed.

1.5 Submittals

  • Manufacturer datasheets for every item with a clause-by-clause compliance statement.
  • System riser diagram showing door stations, monitors, guard stations, switches and network connections.
  • Shop drawings with device locations, mounting heights, cable routes and door wiring details for each door type.
  • PoE budget calculation per switch and lock power supply calculation with battery autonomy.
  • Call routing plan: which door station calls which monitors, guard stations, phones and mobile users, with time schedules.
  • Evidence of SIP interoperability with the specified IP-PBX, where applicable.
  • Description of the mobile application service: data hosting location, subscription terms (if any) and number of users per unit.
  • Testing and commissioning procedure, and as-built documentation at handover.

1.6 Quality Assurance

  • The Contractor shall have completed at least [3] IP intercom projects of similar size within the last [5] years, with references.
  • Technicians shall hold manufacturer training certificates for the offered system.
  • Door stations, indoor monitors and guard stations shall be from a single manufacturer to ensure full feature compatibility.
  • Equipment shall be supplied through the manufacturer's authorised channel in Egypt, with local technical support and spare parts.

1.7 Delivery and Storage

  • Equipment shall be delivered in original sealed packaging and stored in a dry, clean and secured area.
  • Indoor monitors shall be installed only after finishing works (painting, dust-producing works) in each unit are complete; back boxes may be installed earlier.

1.8 Warranty

  • All equipment and installation shall be warranted for [24] months from the date of provisional acceptance.
  • The Contractor shall respond to faults within [24] hours during the warranty period.
  • Firmware and application updates released during the warranty period shall be supplied and installed free of charge.

1.9 Spare Parts and Maintenance

  • Spare indoor monitors of not less than [3%] of installed quantity, and [1] spare door station of each type.
  • The Contractor shall guarantee availability of spare parts in Egypt for not less than [5] years.

PART 2 — PRODUCTS

2.1 System Description and Architecture

  • The system shall be fully IP-based over standard Ethernet and Category 6 cabling, using PoE for door stations and indoor monitors.
  • Calls shall be audio and video from door station to indoor monitor, with two-way audio and door release from the monitor.
  • Each building entrance shall call any unit in the building; villa and apartment door stations shall call their own unit; any door station shall be able to call the guard station.
  • Residents shall be able to call the guard station from the indoor monitor, and intercom calls between units shall be possible where enabled by management.
  • The system shall operate locally without dependence on the internet; internet is required only for the mobile application service.
  • Capacity: not less than [number of units] units with [20%] spare for expansion.

2.2 Door Stations — General Requirements

  • Camera: minimum 2 MP colour, wide-angle lens with horizontal field of view not less than 100°, WDR, and IR or white-light illumination for night operation.
  • Audio: full-duplex hands-free with echo cancellation and noise suppression; loudspeaker output sufficient for outdoor street noise.
  • Network: 10/100 Mbps Ethernet; SIP (RFC 3261); audio codecs G.711 and G.722; video codec H.264.
  • Power: PoE IEEE 802.3af or IEEE 802.3at, with optional 12 V DC input.
  • Enclosure: aluminium alloy or stainless-steel front panel; IP65 minimum to IEC 60529; IK08 minimum to IEC 62262 (IK09 or higher for public entrances).
  • Operating temperature: −20 °C to +60 °C; suitable for direct sun exposure, or a rain/sun hood shall be supplied.
  • Built-in relay output for door release, input for exit button and input for door contact.
  • Tamper alarm to the guard station when the unit is removed from its mounting.
  • Backlit buttons or display with Arabic and English user prompts; voice prompts for call progress.

2.3 Villa Door Stations

  • Single or dual call button as required for [number of households per villa].
  • Surface or flush mounting with rain hood.
  • Optional integrated card reader (13.56 MHz) and/or keypad for resident entry [required / not required].

2.4 Apartment Building Door Stations

  • Keypad and display, or touch screen of not less than [7 inches], with a searchable resident directory and direct apartment number dialling.
  • Resident entry by PIN code, card (13.56 MHz encrypted credentials) and mobile/QR code for visitors [as required].
  • Optional face recognition entry with liveness detection [required / not required].
  • Capacity not less than [number of apartments per entrance] apartments per door station.
  • Apartment floor door stations (if specified): compact unit with single call button at each apartment door.

2.5 Indoor Monitors

  • Colour touch screen [7 inch / 10 inch], resolution not less than 1024 × 600.
  • Hands-free full-duplex audio with echo cancellation; volume and ringtone adjustment.
  • Functions: answer, door release (at least two locks), monitoring of door stations and up to [8] IP cameras via RTSP/ONVIF, call guard station, unit-to-unit call, do-not-disturb, missed call snapshots and message display.
  • PoE IEEE 802.3af powered, with optional 12 V DC input.
  • Alarm inputs [8] for local sensors (door, smoke, panic), reporting to the guard station [optional].
  • User interface in Arabic and English.
  • Surface mounting on a standard back box or bracket; installation height 1.45–1.6 m to screen centre.

2.6 Guard / Concierge Station

  • Desktop unit with colour screen not less than 7 inches and handset, or PC management software with headset, as specified.
  • Receive calls from all door stations and indoor monitors, with call queue, caller identification and video.
  • Call any unit, transfer a door station call to a unit, and release any door.
  • Call and event log including door release events and tamper alarms, with export.
  • Management software: device status monitoring, resident directory management, card/PIN management, firmware updates and configuration backup.

2.7 SIP Compatibility

  • Door stations and guard stations shall register to a standard SIP server or IP-PBX and place calls to SIP phones and SIP video phones.
  • Door release from a SIP phone by DTMF code (RFC 4733 or SIP INFO), with configurable code.
  • Peer-to-peer SIP calling without a server shall be supported for small installations.
  • The Contractor shall demonstrate interoperability with the project IP-PBX [make and version to be stated by the Employer] during testing.

2.8 Door Release and Door Hardware Interface

  • Lock relays shall be dry contacts rated not less than [30 V DC, 2 A], configurable for normally open or normally closed and with adjustable release time of 1–20 seconds.
  • For building entrances, the lock relay shall be in a secure relay module installed on the protected side of the door, so that removing the outdoor station cannot release the lock.
  • Electromagnetic locks (fail-safe) of not less than [280 kg / 600 lb] holding force, or electric strikes [fail-safe / fail-secure] as indicated per door.
  • Doors on escape routes shall use fail-safe locking and shall release on fire alarm signal, and on loss of power, in accordance with the Egyptian fire protection code; a green break-glass emergency release unit shall be provided at each such door.
  • Exit push button on the protected side, and door contact for door-open-too-long and forced-door alarms.
  • Lock power supply: regulated 12 V or 24 V DC, sized for the lock current plus 25% margin, with standby battery for [4] hours minimum and fire alarm input.
  • Suppression diode or varistor across each lock coil.

2.9 Mobile Application and Call Forwarding

  • Calls not answered on the indoor monitor within [configurable time] shall be forwarded to the resident's smartphone, or ring simultaneously, as set by the resident.
  • Application for Android and iOS supporting live video, two-way audio, door release, call history and push notifications.
  • Not less than [4] mobile users per unit, managed by the resident or by management.
  • Encrypted connection between devices, cloud service and application; the cloud service shall be optional and can be disabled.
  • Any recurring cloud subscription fees shall be declared in the offer.

2.10 Lift Integration (Optional)

  • When a resident releases the entrance door for a visitor, the system shall enable the lift for the resident's floor only, for a configurable time.
  • Residents using a card or face recognition shall be granted access to their own floor.
  • The interface shall be by lift control module with relay outputs per floor, or by a high-level interface agreed with the lift manufacturer.
  • The Contractor shall coordinate the interface with the lift contractor; fire service and emergency lift operation shall not be affected.

2.11 PoE Power and UPS

  • PoE switches shall be managed, IEEE 802.3af/at, with a PoE budget not less than the sum of connected device maximum power plus 30%.
  • Switches feeding door stations and guard stations shall be connected to a UPS with autonomy of not less than [30 minutes], 220–240 V AC, 50 Hz.

2.12 Network Requirements

  • The intercom system shall be in a dedicated VLAN (IEEE 802.1Q), isolated from residents' and guests' internet networks.
  • QoS: voice and video traffic shall be marked with DSCP and prioritised end to end.
  • Network performance between any two intercom devices: one-way latency not more than 150 ms, jitter not more than 30 ms and packet loss not more than 1%.
  • Bandwidth allowance of [4 Mbps] per simultaneous video call; IGMP snooping where multicast is used.
  • Cabling: Category 6 U/UTP or better, LSZH; permanent link not exceeding 90 m and channel 100 m.

2.13 Security Requirements

  • No default passwords; strong passwords and account lock-out after [5] failed attempts.
  • HTTPS (TLS 1.2 or higher) for web management; SIP over TLS and SRTP where supported by the call parties.
  • Signed firmware, with security updates from the manufacturer.
  • Unused services disabled; management access restricted to the management VLAN.

PART 3 — EXECUTION

3.1 Examination

  • Survey each entrance and verify mounting surfaces, door types, lock types, lighting at night, sun exposure and cable routes before installation.

3.2 Installation

  • Door stations shall be mounted with the camera at 1.5–1.6 m above finished floor level, or as required for accessibility, facing away from direct sunlight where possible.
  • Back boxes and cable entries of outdoor units shall be sealed against water ingress.
  • Lock power supplies and relay modules shall be installed on the protected side in accessible enclosures.
  • Indoor monitors shall be installed at the heights in Clause 2.5 near the main entrance of each unit.

3.3 Cabling and Labelling

  • All cables shall be labelled at both ends according to ANSI/TIA-606, and every copper link shall be certified to ANSI/TIA-568.2-D.
  • Lock power cables shall be sized for the voltage drop not exceeding 10% at the lock.

3.4 Configuration and Programming

  • Assign IP addresses and SIP accounts per approved schedule.
  • Program call routing, resident directory, door release times, card/PIN credentials and schedules.
  • Configure mobile application users for each unit at handover with the resident or management.
  • Apply the security settings in Clause 2.13 and back up all configurations.

3.5 Testing and Commissioning

TestAcceptance criterion
Call testEvery door station calls every assigned monitor, guard station and SIP extension; call set-up within 2 seconds
Audio qualityClear two-way audio without echo or noticeable delay at the door station and monitor
Video test, day and nightVisitor face clearly visible at 0.5–1.0 m from the door station in daylight, backlight and darkness
Door releaseEvery door releases from monitor, guard station, SIP phone and mobile application; release time as programmed
Door hardware and fire releaseExit button, door contact alarms and fire alarm release operate; fail-safe doors release on power loss
Mobile call forwardingCall reaches the smartphone over cellular data within [5] seconds of forwarding; video, audio and release work
Lift integrationVisitor release and resident credential enable only the correct floor
Power failureSystem operates on UPS and lock battery for the specified durations
Security checkNo default passwords; VLAN isolation and HTTPS verified; tamper alarm received

3.6 Training

  • Guard station operators and building management: [1] day covering calls, transfers, door release, directory and credential management.
  • System administrator: [1] day covering configuration, backups, firmware and troubleshooting.
  • A short Arabic/English user guide for residents covering the indoor monitor and mobile application.

3.7 Documentation and Handover

  • As-built drawings, riser diagram, IP address and SIP account schedule, and switch port map.
  • Configuration backups, administrator passwords in a sealed envelope and licence certificates.
  • Signed test sheets, operation and maintenance manuals and warranty certificates.

Related tools and products

Frequently asked questions

Does an IP intercom system need the internet to work?

No. The specification requires the system to work fully on the local network between door stations, monitors and the guard station without internet. Internet is needed only to forward calls to the mobile application.

What protection rating suits an outdoor door station?

The specification requires IP65 minimum to IEC 60529 and IK08 minimum to IEC 62262, with IK09 or higher for public entrances, and an operating range of −20 °C to +60 °C or a supplied sun hood.

Why must the lock relay be on the protected side of the door?

If the release relay is inside the outdoor unit, removing the unit and bridging its terminals can open the lock. The specification therefore requires a secure relay module on the protected side at building entrances.

Can the intercom connect to the company telephone system?

Yes. The specification requires SIP to RFC 3261 with registration to any standard SIP server, door release from a SIP phone by DTMF code, and proof of interoperability with the project IP-PBX during testing.

Need help designing your project?