Skip to Content

Technical Specification: Active Network (LAN Switching and Wi-Fi)

This specification covers the active network: core, distribution, access and PoE switches, edge firewall, Wi-Fi access points, wireless survey, design documentation, testing and commissioning. It is written for consultants, engineers and contractors to insert into tender documents with light editing.

Vendor-neutral, no brand names. Review it against the code adopted for your project and fill in the values in [brackets].

PART 1 — GENERAL

1.1 Scope of Work

The Contractor shall design, supply, install, configure, test and commission a complete active network for [project name], including LAN switching, edge security and wireless LAN, ready to carry data, voice, video surveillance and building systems traffic. The scope includes:

  • Core switches [2] in a redundant configuration, distribution switches where a three-tier design is required, and access switches for [number of TRs].
  • PoE access switches for IP cameras, IP phones, access points and other powered devices, quantity [number of PoE ports].
  • Optical transceivers, stacking and direct-attach cables needed for all uplinks.
  • Edge firewall/router [2] in high availability, with security subscriptions.
  • Wi-Fi access points [number of indoor APs / outdoor APs] with a WLAN controller or cloud management platform.
  • Wireless site survey, coverage design, network design documentation (IP plan, VLAN plan), configuration, testing, commissioning, training and handover.

Passive cabling, racks and earthing are covered in the Structured Cabling System section.

1.2 Related Sections and Systems

  • Structured Cabling System.
  • IP video surveillance, access control, IP telephony, public address and building management systems connected to the network.
  • UPS and power distribution to racks; HVAC for TRs and ERs.
  • Internet service provider circuits (by the Employer unless stated otherwise).

1.3 Reference Standards

  • IEEE 802.3 — Ethernet, including IEEE 802.3af, 802.3at and 802.3bt (Power over Ethernet) and IEEE 802.3az (Energy Efficient Ethernet).
  • IEEE 802.1Q — Bridges and Bridged Networks (VLANs, priority, RSTP and MSTP).
  • IEEE 802.1AX — Link Aggregation (LACP).
  • IEEE 802.1AB — Link Layer Discovery Protocol (LLDP).
  • IEEE 802.1X — Port-Based Network Access Control.
  • ITU-T G.8032 — Ethernet ring protection switching.
  • IEEE 802.11ax (Wi-Fi 6) and IEEE 802.11k, 802.11v and 802.11r for assisted roaming; Wi-Fi Alliance certification including WPA3.
  • RFC 3411–3418 (SNMPv3), RFC 5424 (Syslog), RFC 5905 (NTPv4), RFC 3376 (IGMPv3), RFC 4541 (IGMP/MLD snooping), RFC 2328 (OSPFv2), RFC 5798 (VRRPv3), RFC 2865 (RADIUS), RFC 8907 (TACACS+).
  • RFC 2544 — Benchmarking methodology for network interconnect devices.
  • IEC 62368-1 — Safety of audio/video, information and communication technology equipment.
  • IEC 60529 — Degrees of protection provided by enclosures (IP code), for outdoor equipment.
  • Type approval of the National Telecom Regulatory Authority (NTRA) of Egypt for radio equipment, where required.

1.4 Definitions

  • PSE / PD: power sourcing equipment (PoE switch) / powered device.
  • PoE budget: total power the switch can deliver simultaneously to all PoE ports.
  • SSID: wireless network name broadcast by an access point.
  • RSSI / SNR: received signal strength (dBm) / signal-to-noise ratio (dB) as measured at the client location.
  • HLD / LLD: high-level design / low-level design.

1.5 Submittals

  • Datasheets for every device with a compliance statement against each clause of this section (clause, requirement, offered value, reference page).
  • High-level design: topology diagram, redundancy concept, routing and security zones.
  • PoE budget calculation per access switch based on the maximum class power of connected devices.
  • Predictive wireless survey report with heat maps for RSSI, SNR and channel overlap per floor.
  • Bill of materials with part numbers, licences and subscription terms.
  • Manufacturer authorisation letter for this project and confirmation that offered models are not announced end-of-sale.
  • Low-level design, IP plan and VLAN plan for approval before configuration.
  • Test procedures and acceptance forms, then as-built documentation at handover.

1.6 Quality Assurance

  • The Contractor shall be an authorised partner of the offered manufacturer, with at least [2] engineers holding current professional-level networking certifications and [3] similar projects completed in the last [5] years.
  • All switches, firewalls and access points shall preferably be from one manufacturer, or proven interoperable with a common management platform.
  • Products shall be new, original, carry official local warranty and be supported by a local service centre in Egypt.

1.7 Delivery and Storage

  • Deliver equipment in sealed original packaging with serial numbers listed in the delivery note.
  • Store in a clean, dry, air-conditioned area. Install only after TRs are clean, secured, air-conditioned and powered from the UPS.

1.8 Warranty and Support

  • Hardware warranty of [3] years minimum from provisional acceptance, with advance replacement of failed units within [next business day].
  • Software and firmware updates and manufacturer technical support throughout the warranty period.
  • Security subscriptions and management licences for [3] years, registered in the Employer's name.
  • Offered products shall not reach end-of-support within [5] years from delivery.

1.9 Spare Parts

  • Supply [1] spare access switch of each model, [2] spare transceivers of each type and [1] spare access point per [50] installed.

PART 2 — PRODUCTS

2.1 System Architecture

The network shall use a [collapsed core / three-tier] hierarchical design. Core switches shall be redundant (stacking or multi-chassis link aggregation) with dual-homed uplinks from every access switch using LACP over fibre. Routing between VLANs shall be performed at the core. Each service (management, data, voice, CCTV, building systems, staff Wi-Fi, guest Wi-Fi) shall be in a separate VLAN and subnet. The edge firewall shall separate the internal network, DMZ and internet. Sites where cameras or devices are connected in rings (e.g. outdoor perimeters) shall use ring protection.

2.2 Core Switches

  • Layer 3 managed switch, 19-inch rack mount, non-blocking wire-speed switching on all ports.
  • Ports: not less than [24 / 48] × 1/10G SFP+ and [2 / 4] × 40/100G QSFP uplink or stacking ports.
  • Redundant hot-swappable power supplies 220–240 V AC 50 Hz and redundant fans.
  • MAC table not less than [32,000] entries; routing table not less than [8,000] IPv4 routes; jumbo frames.
  • Routing: static, OSPFv2, VRRP, policy-based routing, DHCP relay, IPv4 and IPv6; PIM-SM where multicast routing is required.
  • Stacking or multi-chassis link aggregation so that the failure of one core unit does not interrupt dual-homed access switches.
  • VLANs (4,094 IDs), 802.1Q trunks, RSTP/MSTP, LACP, LLDP, IGMP snooping and querier.
  • QoS: not less than 8 queues per port, classification by 802.1p/DSCP/ACL, strict priority and weighted scheduling, rate limiting.
  • ACLs at Layer 2 to Layer 4, in hardware.

2.3 Distribution Switches (where required)

  • Layer 3 managed, [24] × 1/10G SFP+ ports, [2–4] × 10/25/40G uplinks, redundant power supplies, with the same Layer 2/Layer 3, QoS and security features as the core.

2.4 Access Switches (PoE)

  • Managed Layer 2 (with static routing as a minimum), [24 / 48] × 10/100/1000BASE-T ports, and [number] × 1/2.5/5 Gb/s multi-gigabit ports for Wi-Fi 6/7 access points.
  • Uplinks: not less than [4] × 1/10G SFP+.
  • PoE to IEEE 802.3af (15.4 W per port at PSE) and 802.3at (30 W per port at PSE) on all copper ports; IEEE 802.3bt Type 3 (60 W) or Type 4 (90 W) on [number] ports where required.
  • PoE budget per switch not less than the calculated load plus [20%] spare, and not less than [370 W] for 24-port and [740 W] for 48-port models.
  • PoE management: per-port priority, scheduling, power monitoring and automatic recovery of hung PDs.
  • Switching capacity non-blocking; MAC table not less than [16,000] entries.
  • VLANs, voice VLAN, 802.1Q, RSTP/MSTP, LACP, LLDP/LLDP-MED, IGMP v1/v2/v3 snooping with querier and fast leave, QoS with not less than 8 queues.
  • Ring protection to ITU-T G.8032 with recovery time not exceeding [50 ms] where ring topology is used.
  • Stacking optional for access switches in the same TR [required / not required].
  • Fanless or low-noise models for installation outside equipment rooms.
  • Outdoor or industrial locations: hardened switches with operating temperature [-40 °C to +75 °C], DIN-rail mounting, wide-range DC input and surge protection on ports.

2.5 Optical Transceivers

  • Pluggable SFP/SFP+ modules to IEEE 802.3 (e.g. 1000BASE-SX/LX, 10GBASE-SR/LR) matching the fibre type and link length.
  • Digital diagnostics (DDM) for transmitted/received power and temperature.
  • Modules shall be supplied or formally supported by the switch manufacturer.

2.6 Management Features (All Switches)

  • Secure management by HTTPS, SSH and console; SNMPv2c/v3; RMON; Syslog; NTP; LLDP.
  • Port mirroring, cable diagnostics, configuration backup/restore and dual firmware images.
  • Central network management platform [on-premises / cloud] covering all switches and access points: topology, inventory, alarms, PoE usage, configuration templates, firmware management and reports, with licences for [number] devices plus [25%] growth.

2.7 Security Features (All Switches)

  • IEEE 802.1X with MAC authentication bypass for devices without a supplicant, dynamic VLAN assignment by RADIUS.
  • Administrative authentication by RADIUS or TACACS+ with role-based access and accounting.
  • Port security (MAC limiting), DHCP snooping, dynamic ARP inspection, IP source guard, BPDU guard, storm control.
  • Layer 2–4 ACLs; dedicated management VLAN; ability to disable unused services (Telnet, HTTP, SNMPv1).

2.8 Edge Firewall / Router

  • Stateful next-generation firewall in high-availability pair (active/passive or active/active) with session synchronisation.
  • Firewall throughput not less than [x Gbps]; threat protection throughput (with IPS and application control enabled) not less than [y Gbps]; concurrent sessions not less than [z]. Values shall be quoted from the manufacturer's published datasheet.
  • Interfaces: not less than [8] × 1G and [2] × 10G SFP+; separate dedicated HA and management ports.
  • Functions: NAT, static and dynamic routing, dual WAN with failover and load balancing, application identification and control, intrusion prevention, anti-malware, web filtering, DNS filtering, SSL/TLS inspection for selected traffic.
  • VPN: IPsec site-to-site and remote-access VPN for [number] concurrent users with multi-factor authentication support.
  • Integration with directory services for user-based policies; logging and reporting with local or central storage of logs for [90 days].
  • Security subscriptions for [3] years.

2.9 Wi-Fi Access Points

  • IEEE 802.11ax (Wi-Fi 6) or later, Wi-Fi Alliance certified; [Wi-Fi 6E / Wi-Fi 7 where the 6 GHz band is permitted by NTRA].
  • Concurrent dual-band 2.4 GHz and 5 GHz radios; spatial streams not less than [2×2:2] for standard areas and [4×4:4] on 5 GHz for high-density areas.
  • OFDMA, MU-MIMO (downlink and uplink), BSS colouring and target wake time.
  • Uplink: [1 / 2.5] Gb/s Ethernet; powered by IEEE 802.3at with all radios and ports at full function (or 802.3bt where stated by the manufacturer).
  • Security: WPA3-Personal, WPA3-Enterprise, WPA2 for legacy clients, 802.1X/RADIUS, Protected Management Frames.
  • Roaming: 802.11k, 802.11v, 802.11r; band steering; airtime fairness; load balancing between APs.
  • Not less than [8] SSIDs per radio, each mapped to a VLAN, with per-SSID rate limiting.
  • Wireless intrusion detection: rogue AP detection and classification.
  • Indoor: ceiling or wall mount with locking bracket. Outdoor: IP67 to IEC 60529, operating temperature [-20 °C to +55 °C], with surge protection.
  • Integrated antennas for indoor models; external antenna options for outdoor/long-range links.

2.10 WLAN Controller / Management Platform

  • [Hardware controller / virtual controller / cloud management] supporting [number] APs with [25%] growth, with redundancy for on-premises controllers.
  • Automatic radio resource management (channel and power), client and AP monitoring, heat maps, alarms and reports.
  • Seamless roaming across all APs within the site, with fast roaming for voice clients.
  • Guest management: captive portal in Arabic and English, vouchers or [SMS] registration, session time and bandwidth limits, terms-of-use page, and guest logs retained for [period] as required by applicable regulations.
  • Licences for [5] years where the platform is licence-based.

2.11 Guest Network

  • Separate SSID and VLAN, internet access only, routed through the firewall to a dedicated zone.
  • Client isolation on the AP and the switch so that guest devices cannot see each other or any internal network.
  • Rate limit per client of [5 Mbps down / 2 Mbps up] and total guest bandwidth cap of [x%] of internet capacity.

PART 3 — EXECUTION

3.1 Examination

  • Verify that the structured cabling is installed and certified, that racks are earthed, that UPS power and air-conditioning are available in TRs, and that AP outlet locations match the approved wireless design.

3.2 Wireless Site Survey and Coverage Design

  • Perform a predictive survey on scaled floor plans with correct wall materials and attenuation values, and validate on site in representative areas by an AP-on-a-stick survey before AP positions are fixed.
  • Design targets on 5 GHz, measured at 1.0–1.5 m above floor with a calibrated survey tool:
    • Primary coverage RSSI ≥ [-67 dBm] in [95%] of covered areas where voice or real-time applications are used; ≥ [-70 dBm] for data-only areas.
    • Secondary coverage (second-strongest AP) ≥ [-75 dBm] in areas requiring seamless roaming.
    • SNR ≥ [25 dB]; co-channel overlap minimised.
  • Channel plan: 2.4 GHz on non-overlapping channels 1, 6 and 11 only, 20 MHz width; 5 GHz using 20 or 40 MHz width (80 MHz only in low-density areas).
  • Capacity design: not more than [30–50] active clients per AP radio according to the application; high-density areas (halls, meeting rooms) designed per seat count [number of users].
  • After installation, carry out a post-installation validation survey and adjust AP positions or power until targets are met. These are design targets measured by the survey tool; actual client readings may differ by device.

3.3 Network Design Documentation

  • Low-level design: device naming convention, port assignments, uplinks, stack/redundancy configuration, STP root placement, routing, QoS policy and security policy.
  • IP addressing plan: subnets, gateways, DHCP scopes and reservations, static addresses for infrastructure and servers.
  • VLAN plan (example, to be adapted):
VLAN IDNameSubnetPurpose
[10]MGMT[10.0.10.0/24]Network device management
[20]DATA[10.0.20.0/23]Wired user computers
[30]VOICE[10.0.30.0/24]IP phones
[40]CCTV[10.0.40.0/23]Cameras and recorders
[50]BMS-ACS[10.0.50.0/24]Access control, building systems
[60]WIFI-STAFF[10.0.60.0/23]Staff wireless clients
[70]WIFI-GUEST[172.16.70.0/23]Guest internet only

3.4 Installation

  • Mount equipment in racks per approved elevations with cable managers; connect dual power supplies to separate PDUs; bond chassis to the rack earth.
  • Install APs at approved locations, secured with locking brackets, labelled with their name visible from below.
  • Label every switch, uplink cable and transceiver port at both ends.
  • Upgrade all devices to the manufacturer's recommended stable firmware before configuration.

3.5 Configuration

  • Configure VLANs, trunks allowing only required VLANs, LACP uplinks, STP with root at the core and edge ports protected by BPDU guard.
  • QoS: voice marked DSCP EF (46) with strict priority; video and critical traffic classes per the approved policy.
  • IGMP snooping with a querier on VLANs carrying multicast (e.g. CCTV), with unknown multicast flooding disabled.
  • DHCP, NTP synchronised to [time source], SNMPv3, Syslog to the management platform, AAA by RADIUS/TACACS+, 802.1X on user ports where specified.
  • Firewall policies on the principle of least privilege; inter-VLAN access only as approved in the security policy.
  • Change all default passwords; disable unused ports (assigned to an unused VLAN) and insecure services; save and back up all configurations.

3.6 Testing and Commissioning

  • Inventory check of serial numbers, licences and firmware versions against the approved list.
  • Link and transceiver checks: link speed, duplex, error counters zero, optical power within DDM thresholds.
  • PoE test: all PDs powered at full load; measured switch PoE consumption recorded against the budget.
  • Redundancy tests: removal of one uplink, one power supply, one core member and failover of the firewall pair. Service shall recover within [1 s] for LACP/stacking events, [3 s] for RSTP and [50 ms] for G.8032 rings, without loss of configuration.
  • VLAN isolation and inter-VLAN ACL tests; guest isolation test from a guest client to internal subnets and to other guest clients.
  • Throughput test between access and core on sample links per RFC 2544 or equivalent traffic generation, with no packet loss at [line rate].
  • Multicast test with all cameras streaming to recorders and no flooding to other ports.
  • 802.1X and RADIUS authentication tests with approved and non-approved devices.
  • Wi-Fi: post-installation survey report against design targets, roaming test with a voice call walking through [defined route] without drop, WPA3/WPA2 client connection tests, captive portal test.
  • Stability period of [7] days of operation without critical faults before provisional acceptance.

3.7 Training

  • Provide [3] days of hands-on administrator training on switch, firewall, WLAN and management platform operation, backup, firmware upgrade and troubleshooting, with training material in Arabic or English.

3.8 Documentation and Handover

  • As-built HLD/LLD, topology diagrams, IP and VLAN plans, port maps and rack elevations.
  • Final configuration files of all devices, firmware versions, licence and warranty certificates registered in the Employer's name.
  • Administrator credentials handed over in a sealed envelope or password vault, to be changed by the Employer.
  • Test reports, survey reports and the signed acceptance certificate.

Related tools and products

Frequently asked questions

How is the PoE budget of a switch calculated?

Add the maximum class power of every connected device (camera, phone or access point) from its datasheet, add at least 20% spare, and select a switch whose total budget is not less than the result, checking that each port supports the class of its device (af, at or bt).

What signal strength should a Wi-Fi design target?

A common target is -67 dBm or better on 5 GHz where voice and video calls are used, and -70 dBm for data areas, with an SNR of at least 25 dB. These are design targets stated in the tender and verified by the post-installation survey.

Why is the guest network placed in a separate VLAN?

To prevent guest devices from reaching the internal network, cameras and servers, to stop them seeing each other, and to apply per-user rate limits with internet-only access through the firewall.

Should the tender require cloud management or an on-premises controller?

The specification leaves the choice to the consultant. Cloud management suits multi-branch sites and simple monitoring, while an on-premises controller suits sites that require data and management to stay on site or lack a stable internet connection.

Need help designing your project?