Most CCTV projects start with one question: how many cameras? The right answer does not come from counting corners but from the floor plan itself: where the person you need to recognise stands, how far away, and what blocks the view. That is why Do Link added a free camera layout tool to its engineering tools.
Step 1: the plan and its scale
Upload the floor plan (JPG, PNG or WEBP), draw a line over a distance you know, such as a door or a wall, and type its length in metres. From then on every distance is in metres at the scale you set. The plan stays in your browser; it is sent to us only if you choose to attach it to a quotation request.
Step 2: walls and cameras
Draw the walls that block the view, then place cameras. For each camera you pick one of our models or enter generic specifications, and set the mounting height, tilt and direction. Where the required model specifications are available, the tool displays selectable lens options or an approximate zoom control and recalculates the angle of view.
How coverage is drawn: DORI distances
The tool uses the DORI pixel-density model from IEC 62676-4:2014 to estimate the level of visual detail available at the target. These thresholds are design guidelines, not guarantees of successful detection, recognition or identification:
- Detect, 25 px/m: detect the presence of a person.
- Observe, 62.5 px/m: observe general characteristics, such as clothing.
- Recognise, 125 px/m: recognise a previously seen person under suitable conditions.
- Identify, 250 px/m: obtain sufficient visual detail to support identification under suitable conditions.
These distances are worked out for every direction inside the angle of view, at target height (a standing person's head, for example), taking the camera height and tilt into account, then limited by the walls that block the view. The tool also shows the estimated ground-level blind zone in front of the camera's mounting position, an approximate frame preview of the person and a side view of the view limits. Coverage is limited by the entered night illumination range, where specified, but that range does not guarantee successful recognition or identification at night.
IEC 62676-4:2025 introduces updated pixel-density levels. The Do Link tool displays these for reference, while its coverage map and design verdicts continue to use the legacy 2014 DORI model.
Step 3: network and cables
Add switches and recorders on the plan and press "connect unconnected cameras". The tool connects unconnected IP cameras to the nearest suitable switch or PoE-enabled NVR with an available port and sufficient estimated power, within a 90 m cable run. Analog cameras are connected to suitable DVRs with available channels, using 300 m as a preliminary auto-link limit; actual coaxial transmission distances must be verified against the equipment datasheets. Cameras without a suitable connection remain unconnected and are flagged.
Each camera cable is estimated using an L-shaped horizontal route, the mounting height and 3 m of slack. Cable quantities account for cutting individual runs from 305 m boxes or rolls. Backbone links, patch cords and actual installation detours are excluded, and overlength runs are flagged for redesign.
Step 4: bill of materials and report
The tool lists every model, the suggested recorder, the load on each switch and the cable lengths. Estimated storage for 30 days is calculated using Hikvision's recommended IP camera bitrates, assuming H.265, 25 fps, continuous 24-hour recording and a 10% storage allowance. For analog systems, the actual storage requirement depends on the DVR's encoding settings and supported recording frame rate. One click sends the project to the storage calculator, the PoE calculator or the recorder selector, or prints a full report with the camera schedule and warnings.
Limits you should know
This is a preliminary geometric estimate for an ideal lens on a plan view. It does not replace a site visit or the datasheets: real lighting, face angle, reflections, video compression and cable routes differ from site to site. The tool shows clear warnings when ports, PoE budget or cable length are not enough.
Technical references
- Axis Communications — Pixel density and DORI (IEC 62676-4:2014)
- Axis Communications — Pixel density based on IEC 62676-4:2025
- IEC 62676-4, 2014 and 2025 editions.
- Hikvision recommended bitrate table (H.264 / H.265).
Try the tools yourself: the CCTV layout design tool, the storage calculator, the PoE calculator and the camera and recorder selector. When the design is ready you can request a quotation from inside the tool, or message our sales team on WhatsApp.
Frequently asked questions
Is the tool free?
Yes. It is free, runs in the browser and needs no sign-up.
Is my floor plan sent to Do Link?
No. The plan stays in your browser and reaches us only if you choose to attach it to a quotation request.
Which distance standard is used?
The DORI pixel-density model of IEC 62676-4:2014: detect 25, observe 62.5, recognise 125 and identify 250 pixels per metre, as design guidelines. The 2025 edition levels are shown for reference only.
Can I install directly from the result?
The result is a preliminary estimate; check the site and the datasheets before installation.