APC AP8858 NetShelter Metered Rack PDU, 0U, 1PH, 3.7kW 230V 16A, 18 C13 & 2 C19 Outlets, C20 Inlet

Model AP8858
Product Code: AP8858

APC AP8858 NetShelter Metered Rack PDU, 0U, 1PH, 3.7kW 230V 16A, 18 C13 & 2 C19 Outlets, C20 Inlet

APC AP8858 NetShelter Metered Rack PDU, 0U, 1PH, 3.7kW 230V 16A, 18 C13 & 2 C19 Outlets, C20 Inlet is a Network Rack product. Review its technical specifications and product data to select the right solution from Do Link Egypt.

https://dolinkegypt.com/web/image/product.template/11477/image_1920?unique=a4542c0

The APC AP8858 is a NetShelter Metered Rack PDU that distributes and actively measures power in the IT rack. It mounts vertically in zero U, takes power through an IEC C20 inlet and feeds equipment through 18 C13 and 2 C19 locking outlets, while its LCD and network interface report volts, amps, kW and kWh for capacity planning and overload prevention.

  • 3.7 kW at 230 V 16 A (3.3 kW at 208 V)
  • 18 × C13 and 2 × C19 locking outlets, C20 inlet
  • Real-time metering of volts, amps, kW and kWh with user-defined alarms
  • Remote access via Web, SNMP, CLI and EcoStruxure IT; daisy-chain up to 4 PDUs on 1 IP
  • Operates up to 60 °C, 0U vertical mounting
  • 24-month warranty

This combination does not exist.

  • RACKs
  • Technical Support Before and after sale
  • Fast Delivery All over Egypt
  • Secure Payment Cash on delivery or in branch

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

General
Model AP8858

Key Features

  • Metered rack PDU with LCD display and user-defined alarm thresholds
  • 18 C13 + 2 C19 locking IEC outlets
  • Measures volts, amps, real power (kW) and energy (kWh)
  • Web, SNMP, CLI and EcoStruxure IT management
  • Daisy-chain up to 4 PDUs from one IP address
  • Local USB port for firmware updates
  • 0U vertical mounting, operation up to 60 °C

Best Fit Applications

Server and network racks in data centers, server rooms and telecom rooms that need metered 16 A single-phase power distribution with remote monitoring.

Technical Specifications

BrandAPC by Schneider Electric
ModelAP8858
Product TypeMetered Rack PDU (NetShelter)
Rack Units0U (vertical mounting)
PhaseSingle phase
Capacity3.3 kW at 208 V 16 A / 3.7 kW at 230 V 16 A
Load Capacity3300 VA
Input Voltage200 V / 208 V / 230 V
Rated Current16 A
Input Current Limit20 A
Frequency50/60 Hz
Output Voltage100 V / 200 V / 208 V / 230 V
Input ConnectionIEC 60320 C20 inlet (no cord provided)
Outlets18 × IEC 60320 C13 + 2 × IEC 60320 C19 (locking)
MeteringVolts, amps, real power (kW) and energy (kWh)
ManagementWeb, SNMP, Command Line Interface, EcoStruxure IT
Daisy-chainUp to 4 PDUs from 1 IP address
DisplayLCD
Circuit ProtectionWithout circuit breaker
MountingRack-mounted, vertical, side
Dimensions (H × W × D)902 × 56 × 44 mm
Net Weight2.93 kg
Operating Temperature-5 to 60 °C
Relative Humidity5 to 95 %
CertificationsMETI Denan, VDE
StandardsCSA C22.2 No 60950, IEC 60950, UL 60950-1
In the BoxInstallation guide, rack mounting brackets, serial configuration cable, safety guide
Warranty24 months