Eaton PDUMH32HVATNET Tripp Lite series ATS PDU, 1PH, 2U, 2 IEC 60309 inputs, 10 ft cord, 7.7kW, 32A, 200-240V, 18 Outlets (16) C13 (2) C19, TAA

Model PDUMH32HVATNET
Product Code: PDUMH32HVATNET

Eaton PDUMH32HVATNET Tripp Lite series ATS PDU, 1PH, 2U, 2 IEC 60309 inputs, 10 ft cord, 7.7kW, 32A, 200-240V, 18 Outlets (16) C13 (2) C19, TAA

Eaton PDUMH32HVATNET Tripp Lite series ATS PDU, 1PH, 2U, 2 IEC 60309 inputs, 10 ft cord, 7.7kW, 32A, 200-240V, 18 Outlets (16) C13 (2) C19, TAA is a Product product. Review its technical specifications and product data to select the right solution from Do Link Egypt.

https://dolinkegypt.com/web/image/product.template/11439/image_1920?unique=7db84ab

Eaton PDUMH32HVATNET Tripp Lite series ATS PDU, 1PH, 2U, 2 IEC 60309 inputs, 10 ft cord, 7.7kW, 32A, 200-240V, 18 Outlets (16) C13 (2) C19, TAA. This automatic transfer switch (ATS) PDU takes two power sources and switches the load automatically to the second one if the first fails, so single-corded equipment stays powered.

  • Automatic transfer between two input sources
  • Keeps single-corded equipment powered
  • Rack-mount design
  • Remote monitoring over the network (Netpack / network models)

This combination does not exist.

  • Technical Support Before and after sale
  • Fast Delivery All over Egypt
  • Secure Payment Cash on delivery or in branch

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

General
Model PDUMH32HVATNET

Key Features

  • Automatic transfer between two input sources
  • Keeps single-corded equipment powered
  • Rack-mount design
  • Remote monitoring over the network (Netpack / network models)

Best Fit Applications

Server and network racks fed from two UPS units or two power sources.

Technical Specifications

BrandEaton
ModelPDUMH32HVATNET
Product Length/Depth12.5 in
Product Height3.5 in
Product Width17.5 in
Product Weight13.7 lb
CompliancesFCC Class A; RoHS; CE Marked
CertificationsCSA Std. C22.2; NOM
Form factor2U
Package contentsPDUMH32HVATNET 7.7kW Single-Phase 200-240V ATS / Switched PDU; Rack-mounting brackets; Plug-lock cable retention sleeves; USB configuration cable; Owner’s manual
Operating Temperature32° to 104°F (0° to 40°C)
Mounting directionHorizontal
MaterialMetal
Cord length10 ft
Amperage Rating32A
Electric current - max32
PhaseSingle-phase
Frequency rating50/60 Hz
Number of Outputs C1316
Number of Outputs C192
FeaturesFlex Center
Front Panel LCD DisplayDigital display reports output amps in 3 separately metered load segments (BANK 1: Outlets #1-9; BANK 2: Outlets #10-18; BANK 3: Total Output), whole-PDU output kW load level and input voltage on primary and secondary input lines
Output ReceptaclesC13 C19
LED indicatorsFront panel LEDs confirm amp / kilowatt / voltage reporting information
Minimum required rack depth16 in
Network portsRJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
Overload protectionIncludes two branch-rated 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2 controls the lower row of outlets (8 C13, 1 C19)
Recommended electrical serviceTwo single-phase 32A 200-240V circuits
Output Receptacles DetailsCompatible with Eaton Tripp Lite Power Cords
ReceptaclesEach outlet is individually controllable via remote interface; C13; C19
Input Cord Length10 ft
Switch configurationENTER and MODE switches toggle the digital display to show output amps (Bank 1, Bank 2 and Total), total kW output and input voltage (primary, secondary)
Cord typeSet of two inputs connect to separate PRIMARY and SECONDARY power sources; accepts inputs at all phase angles
Communications CableMicro-USB to USB-A configuration/console access cable
Operating elevation0-10000 ft. (0-3000 m)
Operating temperature range32° to 104°F (0° to 40°C)
Output nominal voltage200-240V
Relative humidity5% to 95% non-condensing
Form Factors Supported2U rackmount
Output Capacity Details7.7kW (240V), 7.4kW (230V), 7.0kW (220V), 6.7kW (208V), 6.4kW (200V); 32A maximum total output; 16A maximum per breakered load bank; 16A maximum per C19 outlet; 10A maximum per C13 outlet
Output Capacity (kW)7.7
Storage temperature-22° to 122°F (-30° to 50°C)
Network Speed10 Mbps 100 Mbps (Fast Ethernet)
Product HighlightsDigital LED display for real-time status and current monitoring; Ethernet network interface for remote access; 2-year limited warranty (Worldwide); Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability; Automatic transfer switching within 1-5 ms; Single-phase IEC309 200-240V 32A Blue (2P+E) input; 16 C13 and 2 C19 230V switched outlets in 2 breakered load banks
PowerAlert SoftwareLX Platform Interface: Power; Alert Device Manager
PDU Plug Type532P9W
PDU TypeAuto-transfer switch
PDU Input Voltage208 230
High Availability PDU FeaturesAuto probe monitoring and reboot (included); Auto-transfer switching; Auto load shedding
PDU Form FactorHorizontal (2U)
Current Measurement Accuracy+/-1%
Power Measurement Accuracy+/-1%
Voltage Measurement Accuracy+/-1%
Total Outlets18